Calibration nozzle for HANA
Flow regulated by nozzles 60,75,90 L/min or without nozzle 115 L / min
Approval:
(E4) 67R010213
(E8) 110R-004686
- Coil resistance - 1.9 Ω
- Operating temperature - 20 ° C to +120 ° C
- Opening time - 2.0 ms
- Closing time - 1.2 ms
- Injection time - 2.9 ms
- Maximum supply pressure - 4.5 bar
- Life - over 500 million cycles
- Body diameter - 28mm Φ
- The width of the body of the plug - 38mm
- Length - 72cm
- Inlet gas - 6mm
- Departure: Gas - 6 mm
Selection of Hana injectors depending on engine power:
Type / Color | A + | Gold | Gold + 2.4 nozzle | Gold + 2.1 nozzle |
Yield HP / on one cylinder at a pressure of 0.8 bar (At maximum load) |
40HP | 33HP | 26HP | 20HP |
Yield HP / on one cylinder at a pressure of 1.0 bar (At maximum load) |
50HP | 40HP | 32HP | 25HP |
Yield HP / on one cylinder at a pressure of 1.2 bar (At maximum load) |
60HP | 50HP | 39HP | 30HP |
The 4-cylinder engine with a capacity of: | 160 ~ 240 HP | 132 ~ 200 HP | 104 ~ 156 HP | 80 ~ 120 HP |
The 6-cylinder engine with a capacity of: | 240 ~ 360 HP | 198 ~ 300 HP | 156 ~ 234 HP | 120 ~ 180 HP |
The 8-cylinder engine with a capacity of: | 320 ~ 480 HP | 264 ~ 400 HP | 208 ~ 312 HP |
160 ~ 240 HP |
Calibration nozzle for HANA
Elbow/nozzle for the AC W03 injection rail with an outlet for mapsensor. Original
Max. flow (at a pressure of 1,6 bar) - 120l/min
The injector VALTEK 32 after rebranding known injectors OMVL SL.
Technical data suitable for OMVL SL / REG FAST.
cod.23809000
GI25-22. For power: < 20 kW
Resistance 1.9 Ohm. Max. gas flow: 120 l / min
BRC 4cyl. original
Resistance of the coil - 1,7 Ω, 40-60 HP/ 1cyl.
BRC original
Flow Rate - 130L/min
Coil resistance - 1.3 Ω